Huawei S5700 Series Switches S5700-52C-PWR-EI-AC Overview
Huawei S5700 Series Switches S5700-52C-PWR-EI-AC is a genuine campus and data-center switching product from Huawei, a worldwide ICT vendor with a strong portfolio of enterprise switches, routers and data-center hardware. Belonging to the Huawei S5700 Series family, the S5700-52C-PWR-EI-AC unit is built to the original factory specification, so it integrates with existing Huawei deployments predictably and behaves exactly as the platform documentation describes. In the network, it is suited to access-layer and edge deployments, where reliable wiring-closet operation and straightforward management are the priorities.
This unit follows the original factory specification for the Huawei S5700 Series family, covering its intended role without compatibility surprises. Standard mounting, cabling and management practices apply, and it interoperates with surrounding hardware using the same procedures as other Huawei equipment already deployed in the network.
Typical deployments include access-layer deployments for user, phone and AP connectivity, distribution and core aggregation in campus networks, and top-of-rack and end-of-row switching in data centers. Organizations commonly source it for refresh programs, capacity expansion and spares management, keeping a tested unit on hand so outages stay short and replacements are predictable. The factory detail for this unit reads: “S5700-52C-PWR-EI-AC(48 Ethernet 10/100/1000 PoE+ ports, with 500W AC power supply)”. This makes it a practical choice when original-spec hardware is required at a predictable cost.
Every unit at LinkNewNet is inspected and tested before dispatch, and stock is graded, cleaned and verified for correct operation, including port status, console access and firmware state. Our warranty coverage and responsive technical support protect the purchase after it arrives, and our team can confirm revision levels and software compatibility before you order. For volume requirements we also offer configuration checks and staged delivery options.
Contact our sales team for current availability, lead time and shipping options for the S5700-52C-PWR-EI-AC. We respond quickly with stock status and a firm quote, so you can plan the refresh or expansion with confidence.
Key Specifications
Applications
Enterprise Campus
High-density ports power users, phones and APs at the access layer.
Branch Office
Stackable units simplify branch deployment and management.
Wireless & IoT
PoE budget supports dense wireless and IoT endpoints.
Buying a Pre-Owned S5700-52C-PWR-EI-AC
Verify the unit is tested, firmware confirmed, and condition documented. Every unit is fully tested and warranty covered. Contact our team for current stock and availability.
| Item | S5700(S)-LI/S5710-LI* | S5700-SI* | S5700-EI/S5710-EI/S5720-EI* | S5700-HI/S5710-HI/S5720-HI* | |
|---|---|---|---|---|---|
| Fixed port | LI | S5700-10P-LI-AC/S5700-10P-PWR-LI-AC: 8 × 10/100/1000Base-T,2 × 1000Base-X SFP | |||
| S5700(S)-28P-LI/S5700-28P-PWR-LI/ S5700-28P-LI-BAT/S5700-28P-LI-4AH: 24 × 10/100/1000Base-T, 4 × 1000Base-X SFP | |||||
| S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH: 28 × 1000Base-X,4 of which are dual-purpose 10/100/1000 or SFP, 4 × 1000Base-X | |||||
| S5700-28TP-LI-AC/S5700-28TP-PWR-LI-AC/S5701-28TP-PWR-LI-AC: 24× 10/100/1000Base-T, 2×1000Base-X SFP and 2 dual-purpose 10/100/1000 or SFP | |||||
| S5700-28X-LI/S5700-28X-PWR-LI-AC/ S5701-28X-LI-AC: 24 × 10/100/1000Base-T, 4 × 10GE SFP+ | |||||
| S5700-28X-LI-24S-AC/S5700-28X-LI-24S-DC/ S5701-28X-LI-24S-AC: 28x1000Base-X,4 of which are dual-purpose 10/100/1000 or SFP,4 × 10GE SFP+ | |||||
| S5700(S)-52P-LI/S5700-52P-PWR-LI: 48 × 10/100/1000Base-T, 4 × 1000Base-X SFP | |||||
| S5700-52X-LI/S5700-52X-PWR-LI-AC: 48 × 10/100/1000Base-T, 4 × 10GE SFP+ | |||||
| S5700-52X-LI-48CS-AC:48x1000Base-X(CSFP) or 24 × 1000Base-X, 4 of which are dual-purpose 10/100/1000 or Base-X(CSFP), 4 × 10GE SFP+ | |||||
| SI | S5700-24TP-SI/S5700-24TP-PWR-SI/S5700-28C-SI/S5700-28C-PWR-SI:24 × 10/100/1000Base-T, 4 of which are dual-purpose 10/100/1000 or SFP | ||||
| S5700-26X-SI-12S-AC: 12 × 10/100/1000BASE-T,12×100/1000Base-X,2 × 10GE SFP+ | |||||
| S5700-48TP-SI/S5700-48TP-PWR-SI: 48 × 10/100/1000Base-T, 4 of which are dual-purpose 10/100/1000 or SFP | |||||
| S5700-52C-SI/S5700-52C-PWR-SI: 48 × 10/100/1000Base-T | |||||
| EI | S5700-28C-EI/S5700-28C-PWR-EI: 24 × 10/100/1000Base-T | ||||
| S5700-52C-EI/S5700-52C-PWR-EI: 48 × 10/100/1000Base-T | |||||
| S5700-28C-EI-24S: 20 × 100/1000Base-X, 4 × GE Combo | |||||
| S5710-28C-EI/S5710-28C-PWR-EI-AC: 20 x 10/100/1000Base-T, 4 × GE Combo, 4 × 10GE SFP+ | |||||
| S5710-52C-EI/S5710-52C-PWR-EI/S5710-52C-PWR-EI-AC: 48 x 10/100/1000Base-T, 4 × 10GE SFP+ | |||||
| S5720-32P-EI-AC: 24×10/100/1000Base-T, 4×100/1000Base-X SFP, 4 Gig SFP | |||||
| S5720-52P-EI-AC:48×10/100/1000Base-T, 4 Gig SFP | |||||
| S5720-36C-EI-AC/S5720-36C-PWR-EI-AC: 28×10/100/1000Base-T(4GE Combo SFP), 4×10 GE SFP+ | |||||
| S5720-36C-EI-28S-AC:28×100/1000Base-X SFP(4GE Combo), 4×10GE SFP+ | |||||
| S5720-36PC-EI-AC: 28×10/100/1000Base-T(4GE Combo SFP), 4 Gig SFP | |||||
| S5720-56C-EI-AC/S5720-56C-PWR-EI-AC/S5720-56C-PWR-EI-AC1:48×10/100/1000Base-T, 4×10GE SFP+ | |||||
| S5720-56C-EI-48S-AC: 48×100/1000Base-X SFP, 4×10GE SFP+ | |||||
| S5720-56PC-EI-AC: 48×10/100/1000Base-T, 4 Gig SFP | |||||
| S5720-32X-EI-AC: 24×10/100/1000 Base-T, 4×100/1000Base-X SFP, 4×10 GE SFP+ | |||||
| S5720-32X-EI-24S-AC: 24×100/1000Base-X SFP, 4×10/100/1000Base-T, 4×10GE SFP+ | |||||
| S5720-50X-EI-AC : 46 ×10/100/1000Base-T, 4×10GE SFP+ | |||||
| S5720-50X-EI-46S-AC: 46 ×100/1000Base-X SFP, 4×10GE SFP+ | |||||
| S5720-52X-EI-AC: 48×10/100/1000Base-T, 4×10GE SFP+ | |||||
| HI | S5700-28C-HI: 24 × 10/100/1000Base-T | ||||
| S5700-28C-HI-24S: 24 × 100/1000Base-X | |||||
| S5710-108C-PWR-HI: 48 × 10/100/1000BASE-T, 8 × 10GE SFP+ | |||||
| S5720-32C-HI-24S-AC: 24×100/1000Base-X ,8 of which are dual-purpose 10/100/1000 or SFP, 4×10GE SFP+ | |||||
| S5720-56C-HI-AC/S5720-56C-PWR-HI-AC: 48×10/100/1000Base-T, 4×10GE SFP+ | |||||
| MAC address table | IEEE 802.1d compliance | ||||
| MAC address learning and aging | |||||
| Static, dynamic, and blackhole MAC address entries | |||||
| Packet filtering based on source MAC addresses | |||||
| MAC address entries: S5700S-LI series: 8K, S5700-LI/S5700-SI series: 16K, S5700-EI series: 32K, S5720-EI series: 64K, S5700-HI series: S5700-HI: 32K, S5710-HI: 456K, S5720-HI: 128K | |||||
| VLAN | 4K VLANs | ||||
| Guest VLAN and voice VLAN | |||||
| GVRP | |||||
| MUX VLAN | |||||
| VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports | |||||
| 1:1 and N:1 VLAN Mapping | |||||
| SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series) | |||||
| Ring protection | RRPP ring topology and RRPP multi-instance | ||||
| Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover | |||||
| SEP | |||||
| ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series) | |||||
| STP, RSTP, and MSTP | |||||
| BPDU protection, root protection, and loop protection | |||||
| BPDU Tunnel | |||||
| Reliability | Ethernet OAM (IEEE 802.3ah and 802.1ag) | ||||
| ITU-Y.1731 | |||||
| DLDP | |||||
| LACP | |||||
| E-Trunk(supported by the S5700-SI/S5700-EI/S5700-HI series) | |||||
| BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM (supported by the S5700-EI/S5700-HI series) | |||||
| MPLS features | MPLS L3VPN | ||||
| MPLS L2VPN(VPWS/VPLS) | |||||
| MPLS-TE | |||||
| MPLS QoS | |||||
| Notes: supported by S5710-EI, S5700-HI and S5710-HI | |||||
| IP routing | Static routing | ||||
| RIPv1, RIPv2 and RIPng,ECMP(supported by the S5700-SI/S5700-EI/S5700-HI series) | |||||
| OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI/S5700-HI series) | |||||
| IPv6 features | Neighbor Discovery (ND) | ||||
| Path MTU (PMTU) | |||||
| IPv6 ping, IPv6 tracert, and IPv6 Telnet | |||||
| ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type | |||||
| MLD v1/v2 snooping | |||||
| 6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI/S5700-EI/S5700-HI series) | |||||
| Multicast | IGMP v1/v2/v3 snooping and IGMP fast leave | ||||
| Multicast forwarding in a VLAN and multicast replication between VLANs | |||||
| Multicast load balancing among member ports of a trunk | |||||
| Controllable multicast | |||||
| Port-based multicast traffic statistics | |||||
| IGMP v1/v2/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI/S5700-HI series) | |||||
| QoS/ACL | Rate limiting on packets sent and received by an interface | ||||
| Packet redirection | |||||
| Port-based traffic policing and two-rate three-color CAR | |||||
| Eight queues on each port | |||||
| WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms | |||||
| WRED (supported by the S5710-EI and S5700-HI) | |||||
| Re-marking of the 802.1p priority and DSCP priority | |||||
| Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID | |||||
| Rate limiting in each queue and traffic shaping on ports | |||||
| Security | User privilege management and password protection | ||||
| DoS attack defense, ARP attack defense, and ICMP attack defense | |||||
| Binding of the IP address, MAC address, interface, and VLAN | |||||
| Port isolation, port security, and sticky MAC | |||||
| MFF | |||||
| Blackhole MAC address entries | |||||
| Limit on the number of learned MAC addresses | |||||
| 802.1x authentication and limit on the number of users on an interface | |||||
| AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC | |||||
| SSH v2.0 | |||||
| Hypertext Transfer Protocol Secure (HTTPS) | |||||
| CPU defense | |||||
| Blacklist and whitelist | |||||
| Operating environment | Operating temperature: 0℃–50℃ | ||||
| Relative humidity: 10%–90% (non-condensing) | |||||
| Input voltage | AC: | ||||
| Rated voltage range: 100 V to 240 V AC, 50/60 Hz | |||||
| Maximum voltage range: 90 V to 264 V AC, 47/63 Hz | |||||
| DC: | |||||
| Rated voltage range: –48 V to –60 V, DC | |||||
| Maximum voltage range: –36 V to –72 V DC | |||||
| Note: PoE-support switches do not use DC power supplies. | |||||
| Dimensions (W x D x H) | S5700-10P-LI-AC:250 x 180 x 43.6 mm | ||||
| S5700-10P-PWR-LI-AC:320 x 220 x 43.6 mm | |||||
| S5700-28P-LI/S5700-28TP-LI-AC/S5700-28X-LI/S5700-28X-LI-24S/S5700-24TP-SI/S5700-28C-HI/S5700-28C-HI-24S/ S5701-28X-LI-AC/ S5701-28X-LI-24S-AC/ S5700-52X-LI-48CS-AC: 442 x 220 x 43.6 mm | |||||
| S5700-28P-PWR-LI/S5700-28TP-PWR-LI-AC/S5701-28TP-PWR-LI-AC/S5700-52P-LI/S5700-52P-PWR-LI/S5700-28X-PWR-LI-AC/S5700-52X-LI/S5700-52X-PWR-LI-AC/ S5700-26X-SI-12S-AC/S5700-28P-LI-BAT/S5700-28P-LI-4AH/S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH: 442 x 310 x 43.6 mm | |||||
| S5710-108C-PWR-HI: 442x470.0x87.2 | |||||
| Others: 442 x 420 x 43.6 mm | |||||
| Powerconsumption | S5700-10P-LI-AC<11.5W | ||||
| S5700-10P-PWR-LI-AC<139W | |||||
| S5700-28P-LI<25W | S5700-24TP-SI<40W | S5700-28C-EI<60W | S5700-28C-HI<76W | ||
| S5700S-28P-LI<25W | S5700-26X-SI-12S-AC<42.3W | S5700-28C-EI-24S<63W | S5700-28C-HI-24S<80W | ||
| S5700-28TP-LI-AC<26.4W | S5700-48TP-SI<64W | S5700-52C-EI<88W | S5710-108C-PWR-HI<1680W (PoE:1440W) | ||
| S5700-28TP-PWR-LI-AC<469.7W(PoE:370W) | S5700-28C-SI<56W | S5710-28C-EI<100W | |||
| S5701-28TP-PWR-LI-AC<238.7W(PoE:185W) | S5700-52C-SI<78W | S5710-52C-EI<165W | S5720-32C-HI-24S-AC<172.7W | ||
| S5700-52P-LI<52W | S5700-24TP-PWR-SI<455W(PoE: 370W) | S5700-28C-PWR-EI<842W (PoE: 740W) | S5720-56C-HI-AC<183.3W | ||
| S5700S-52P-LI<52W | S5700-48TP-PWR-SI<907W (PoE: 740W) | S5720-56C-PWR-HI-AC: | |||
| S5700-52C-PWR-EI<930W (PoE: 740W) | |||||
S5700-28P-PWR-LI<436.5W (PoE: 370W) | |||||
| S5710-28C-PWR-EI-AC<942W | |||||
| S5710-52C-PWR-EI/S5710-52C-PWR-EI-AC: < 1043W with two 580W AC supplies(PoE:740W), or <1625W with two 1150W AC supplies(PoE:1440W) | |||||
| S5720-32P-EI-AC <50.7W | |||||
| S5720-52P-EI-AC <60.3W | |||||
S5700-52P-PWR-LI<464.5W (PoE: 370W) | S5720-36C-EI-AC <75.8W | ||||
S5720-36C-PWR-EI-AC : | |||||
| S5720-36PC-EI-AC<74.6W | |||||
| S5720-36C-EI-28S-AC<83.9W | |||||
| S5700-28X-LI<42W | S5720-56C-EI-AC<86.9W | ||||
| S5700-28X-LI-24S<54W | S5720-56C-PWR-EI-AC: without PD: <91.6W, with PD:<889.4W(PoE:740W) | ||||
S5700-28X-PWR-LI-AC <448.8W (PoE: 370W) | S5720-56C-PWR-EI-AC1: without PD: <91.6W, with PD:<1564.8W(PoE:1440W) | ||||
| S5700-52X-LI<61W | S5720-56PC-EI-AC<85.7W | ||||
S5700-52X-PWR-LI-AC <479.3W (PoE: 370W) | S5720-56C-EI-48S-AC<104W | ||||
| S5700-28P-LI-BAT/S5700-28P-LI-4AH<23W | S5720-32X-EI-AC <51.9W | ||||
| S5700-28P-LI-24S-BAT/S5700-28P-LI-24S-4AH<34.1W | S5720-32X-EI-24S-AC<58.9W | ||||
| S5700-52X-LI-48CS-AC<79.9W | S5720-50X-EI-AC<55.3W | ||||
| S5701-28X-LI-AC <39.5W | S5720-50X-EI-46S-AC<81.5W | ||||
| S5701-28X-LI-24S-AC<60W | S5720-52X-EI-AC <61.5W | ||||