Huawei S5700 Series Switches S5700-52P-PWR-LI-AC Overview
Huawei S5700 Series Switches S5700-52P-PWR-LI-AC is a genuine campus and data-center switching product from Huawei, a global ICT provider whose CloudEngine and S-Series platforms are widely deployed in campus and data-center environments. Belonging to the Huawei S5700 Series family, the S5700-52P-PWR-LI-AC unit is built to the original factory specification, so it integrates with existing Huawei deployments predictably and behaves exactly as the platform documentation describes. In the network, it is suited to access-layer and edge deployments, where reliable wiring-closet operation and straightforward management are the priorities.
This unit follows the original factory specification for the Huawei S5700 Series family, covering its intended role without compatibility surprises. Standard mounting, cabling and management practices apply, and it interoperates with surrounding hardware using the same procedures as other Huawei equipment already deployed in the network.
Typical deployments include access-layer deployments for user, phone and AP connectivity, distribution and core aggregation in campus networks, and top-of-rack and end-of-row switching in data centers. Organizations commonly source it for refresh programs, capacity expansion and spares management, keeping a tested unit on hand so outages stay short and replacements are predictable. The factory detail for this unit reads: “48 Ethernet 10/100/1000 PoE+ ports, 4 Gig SFP, AC 110/220”. This makes it a practical choice when original-spec hardware is required at a predictable cost.
Every unit at LinkNewNet is inspected and tested before dispatch, and stock is graded, cleaned and verified for correct operation, including port status, console access and firmware state. Our warranty coverage and responsive technical support protect the purchase after it arrives, and our team can confirm revision levels and software compatibility before you order. For volume requirements we also offer configuration checks and staged delivery options.
Contact our sales team for current availability, lead time and shipping options for the S5700-52P-PWR-LI-AC. We respond quickly with stock status and a firm quote, so you can plan the refresh or expansion with confidence.
Key Specifications
Applications
Enterprise Campus
High-density ports power users, phones and APs at the access layer.
Branch Office
Stackable units simplify branch deployment and management.
Wireless & IoT
PoE budget supports dense wireless and IoT endpoints.
Buying a Pre-Owned S5700-52P-PWR-LI-AC
Verify the unit is tested, firmware confirmed, and condition documented. Every unit is fully tested and warranty covered. Contact our team for current stock and availability.
S5700-52P-PWR-LI-AC Specification | |
MAC address table | IEEE 802.1d compliance MAC address learning and aging Static, dynamic, and blackhole MAC address entries Packet filtering based on source MAC addresses MAC address entries: |
VLAN | 4K VLANs Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports 1:1 and N:1 VLAN Mapping SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series) |
Ring protection | RRPP ring topology and RRPP multi-instance Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover SEP ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series) STP, RSTP, and MSTP BPDU protection, root protection, and loop protection BPDU Tunnel |
Reliability | Ethernet OAM (IEEE 802.3ah and 802.1ag) ITU-Y.1731 DLDP LACP E-Trunk(supported by the S5700-SI/S5700-EI/S5700-HI series) BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM (supported by the S5700-EI/S5700-HI series) |
MPLS features | MPLS L3VPN MPLS L2VPN(VPWS/VPLS) MPLS-TE MPLS QoS Notes: supported by S5710-EI, S5700-HI and S5710-HI |
IP routing | Static routing RIPv1, RIPv2 and RIPng,ECMP(supported by the S5700-SI/S5700-EI/S5700-HI series) OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI/S5700-HI series) |
IPv6 features | Neighbor Discovery (ND) Path MTU (PMTU) IPv6 ping, IPv6 tracert, and IPv6 Telnet ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type MLD v1/v2 snooping 6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI/S5700-EI/S5700-HI series) |
Multicast | IGMP v1/v2/v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics IGMP v1/v2/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI/S5700-HI series) |
Management and maintenance | Virtual cable test Port mirroring and RSPAN (remote port mirroring) Remote configuration and maintenance using Telnet SNMP v1/v2c/v3 RMON Web NMS HGMP System logs and alarms of different levels 802.3az EEE (supported by the S5700(S)-LI, S5710-EI, S5700-HI and S5710-HI) Dying gasp (supported by the S5700-HI, S5710-HI and S5700(S)-LI(except battery LAN switches) NetStream (supported by the S5710-EI, S5700-HI and S5710-HI) sFlow(supported by the S5700(S)-LI/S5700-EI/S5700-HI series) |
Interoperability | Supports VBST (Compatible with PVST/PVST+/RPVST) Supports LNP (Similar to DTP) Supports VCMP (Similar to VTP) |
Operating environment | Operating temperature: 0℃–50℃ Relative humidity: 10%–90% (non-condensing) |
Input voltage | AC: Rated voltage range: 100 V to 240 V AC, 50/60 Hz Maximum voltage range: 90 V to 264 V AC, 47/63 Hz DC: Rated voltage range: –48 V to –60 V, DC Maximum voltage range: –36 V to –72 V DC Note: PoE-support switches do not use DC power supplies. |
S5700-52P-PWR-LI-AC - Deployment Notes
This S5700-52P-PWR-LI-AC switch is suited to wiring-closet, distribution, or core roles depending on the port density and uplink options of the specific model. The port configuration is a key consideration when planning power budgets for attached devices such as IP phones and access points.
For a refresh or expansion, confirm the IOS/NX-OS software release supported by this specific SKU, the fan and power requirements, and the uplink modules that match your existing infrastructure. Our team can verify revision levels and software compatibility before you order.
Every unit at LinkNewNet is inspected and tested before dispatch, and this S5700-52P-PWR-LI-AC variant is graded, cleaned and verified for correct operation, including port status, console access and firmware state. Volume requirements can be staged with configuration checks.
S5700-52P-PWR-LI-AC - Huawei Series Notes
This listing is part of the Huawei enterprise networking product family, sourced and tested by LinkNewNet for enterprise deployment. Huawei switch is typically deployed in campus access, aggregation, or data-center roles. It provides reliable Layer 2/3 switching for user, server and uplink connectivity, and integrates with Huawei iMaster NCE or traditional CLI-based management.
Deployment guidance: When planning this S5700-52P-PWR-LI-AC unit into a network, confirm the software image (VRP / iMaster NCE), the power and cooling profile, and the upstream/downstream interface types that match your existing infrastructure. For a like-for-like refresh, match the feature set of the units already in service so management and automation behave consistently.
Our Huawei reconditioning process: Every pre-owned Huawei unit at LinkNewNet passes a documented reconditioning flow before dispatch - visual inspection, internal cleaning, firmware verification, port-by-port testing, and configuration reset to factory defaults. This ensures the unit you receive operates reliably and integrates cleanly with your existing Huawei management tools.
Related models in this family: S5720-52P-LI, S5720-52P-SI-AC, S5720-32X-EI-AC, S5735-L32ST4X-A1, S5735-L48P4X-A1. Compare specifications to confirm the right port density, feature set and uplink options for your deployment.
Model code: AC = AC power supply - this suffix indicates the feature set, power, or port type of the S5700-52P-PWR-LI-AC, which affects software licensing and regional compliance.







